Tweets

Mass Spec Pro @massspecpro Follow RT : Scale up sample throughput. Scale up range of analysis. Coming soon. join us at to learn mo… https://t.co/yPdNNRWwYm 3 hours 3 min ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Believe me. I understand the pain. 6 days 1 hour ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Ah. So you know the pain we feel on commercial instruments that want 50-8000 mz. Do you have th… https://t.co/f9g3Uaxo8P 6 days 1 hour ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow What sort of mass range are we talking about? 6 days 2 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Stability is ill defined for higher order multipoles anyway. 6 days 3 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Can't you just map out transfer curves (signal versus amplitude) for each element using calibran… https://t.co/p1KzLNM1Ah 6 days 3 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Not that I'm aware of. It's less well defined for multipoles than for simple quadrupolar fields. Let me see if I have anything. 6 days 22 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Might not be able to if it's a center tap transformer 1 week 1 day ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Are you in San Jose? 1 week 1 day ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow If present, they would be at slightly different mz values on each instrument. 2 weeks 14 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow I don't know. 2 weeks 14 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow If it's a tribrid, those frequencies are around 1.1MHz. So they could be pickup of the quad or trap rf.… https://t.co/9WuKrl5PAv 2 weeks 22 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow If you run the same mass range scan and just turn esi off, do you see these same peaks? Also, which model instrument is it? 2 weeks 22 hours ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow https://t.co/m9GhwsAUK5 2 weeks 2 days ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow https://t.co/6L8PgKbCyO 2 weeks 3 days ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow https://t.co/1ISVlZmZfG 2 weeks 4 days ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow https://t.co/lHfP4Or6ui 2 weeks 4 days ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow https://t.co/gT1IUlALLM 2 weeks 4 days ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow Buses in Vancouver are really living up to the Canadian stereotype. https://t.co/vYZwCRFcN6 3 weeks 6 days ago Reply Retweet Favorite
Mass Spec Pro @massspecpro Follow RT : We used gas-phase MD guided by ion/ion chemistry to demonstrate the power of complementary methods for determining… https://t.co/RTFnTo4m6X 1 month 1 day ago Reply Retweet Favorite